ManufacturerAdvantech (2)CUI Inc (1)Cincon (39)Cincon Electronics Co. LTD (1)ETA-USA (32)MEAN WELL USA Inc. (23)NTE Electronics, Inc (2)
-
AC Plug included/requiredRequired (19)
-
ApprovalsCE, cUL, EN60950-1, IEC60950-1, UL60950-1 (3)CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 (8)EN60950-1, IEC60950-1, UL60950-1 (2)
-
Center Pin Length9.5 mm (7)12 mm (12)9 mm (1)
-
CompliancePSE (11)EN60950-1, IEC60950-1, UL60950-1 (2)
-
Connector A PolarityCenter Positive (20)
-
Connector TypeBarrel Connector (20)
-
Cooling MethodConvection (18)
-
DC Output Connector1.5 mm Barrel Plug, Right Angle (1.5x5) (3)2.5 mm Barrel Plug, Right Angle (2.5x5.5) (2)2.1 mm Barrel Plug, Right Angle (2.1x5.5) (5)2.1 mm Barrel Plug (2.1x5.5) (4)1.7 mm Barrel Plug, Right Angle (1.7x4) (3)1.35 mm Barrel Plug, Right Angle (1.35x3.5) (1)2.5 mm Barrel Plug (2.5x5.5) (2)
-
DC Output Cord Length1.2 m (5)1.8 m (11)720 mm (4)
-
EfficiencyLevel VI (20)
-
Factory Pack QuantityFactory Pack Quantity1 (20)
-
Height37 mm (3)31 mm (17)
-
IndustryIndustrial (20)
-
Input Voltage90 VAC to 264 VAC (20)
-
Input Voltage-Max264 VAC (18)
-
Input Voltage-Min90 VAC (18)
-
Isolation Voltage4.24 kVDC (18)
-
Length142 mm (3)120 mm (17)
-
Load RegulationRegulated (20)
-
Maximum Operating Temperature+ 70 C (20)
-
Mechanical StyleExternal (18)
-
Minimum Operating Temperature- 30 C (3)- 20 C (17)
-
Mounting StylesDesktop (20)
-
Number of Outputs1 Output (20)
-
Operating Temperature Range- 30 C to + 70 C (3)- 20 C to + 70 C (17)
-
Output Current-Channel 18.34 A (1)4.17 A (1)2.1 A (2)4.2 A (2)3.36 A (2)2.8 A (1)2.65 A (2)1.05 A (2)5.8 A (2)3.9 A (2)2 A (2)1.5 A (1)
-
Output Power100 W (3)50 W (10)70 W (7)
-
Output Voltage-Channel 112 VDC (5)24 VDC (2)48 VDC (4)15 VDC (2)18 VDC (3)19 VDC (2)36 VDC (2)
-
RegionUniversal (20)
-
RoHSDetails (20)
-
SeriesTRH100A (3)TRH50A (10)TRH70A (7)
-
StandardPSE (11)
-
Unit Weight1.069 lbs (1)10.582189 oz (3)
-
Width58 mm (3)52 mm (17)
Attribute column
Categories
AC DC Adapters
Product |
Inventory |
Pricing(USD) |
Quantity |
Datasheet |
RoHS |
AC Plug included/required |
Approvals |
Center Pin Length |
Compliance |
Connector A Polarity |
Connector Type |
Cooling Method |
DC Output Connector |
DC Output Cord Length |
Efficiency |
Factory Pack QuantityFactory Pack Quantity |
Height |
Industry |
Input Voltage |
Input Voltage-Max |
Input Voltage-Min |
Isolation Voltage |
Length |
Load Regulation |
Maximum Operating Temperature |
Mechanical Style |
Minimum Operating Temperature |
Mounting Styles |
Number of Outputs |
Operating Temperature Range |
Output Current-Channel 1 |
Output Power |
Output Voltage-Channel 1 |
Region |
RoHS |
Series |
Standard |
Unit Weight |
Width |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
TRH100A120-48E12-Level-VI
Cincon |
- |
- |
|
- |
- |
CE, cUL, EN60950-1, IEC60950-1, UL60950-1 |
9.5 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
1.5 mm Barrel Plug, Right Angle (1.5x5) |
1.2 m |
Level VI |
1 |
37 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
142 mm |
Regulated |
+ 70 C |
External |
- 30 C |
Desktop |
1 Output |
- 30 C to + 70 C |
8.34 A |
100 W |
12 VDC |
Universal |
Details |
TRH100A |
PSE |
- |
58 mm |
|
|
TRH100A240-48E13-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, UL60950-1 |
9.5 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
1.5 mm Barrel Plug, Right Angle (1.5x5) |
1.8 m |
Level VI |
1 |
37 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
142 mm |
Regulated |
+ 70 C |
External |
- 30 C |
Desktop |
1 Output |
- 30 C to + 70 C |
4.17 A |
100 W |
24 VDC |
Universal |
Details |
TRH100A |
PSE |
- |
58 mm |
|
|
TRH100A480-21E13-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, UL60950-1 |
9.5 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.5 mm Barrel Plug, Right Angle (2.5x5.5) |
1.8 m |
Level VI |
1 |
37 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
142 mm |
Regulated |
+ 70 C |
External |
- 30 C |
Desktop |
1 Output |
- 30 C to + 70 C |
2.1 A |
100 W |
48 VDC |
Universal |
Details |
TRH100A |
PSE |
1.069 lbs |
58 mm |
|
|
TRH50A120-01E01-Level-VI
Cincon |
45 |
- |
|
- |
Required |
- |
12 mm |
- |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug, Right Angle (2.1x5.5) |
720 mm |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
4.2 A |
50 W |
12 VDC |
Universal |
Details |
TRH50A |
- |
10.582189 oz |
52 mm |
|
|
TRH50A120-11E11-Level-VI
Cincon |
7 |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug (2.1x5.5) |
720 mm |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
4.2 A |
50 W |
12 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A150-01E02-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug, Right Angle (2.1x5.5) |
1.2 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
3.36 A |
50 W |
15 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A150-40E02-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
9.5 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
1.7 mm Barrel Plug, Right Angle (1.7x4) |
1.2 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
3.36 A |
50 W |
15 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A180-01E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug, Right Angle (2.1x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
2.8 A |
50 W |
18 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A190-01E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug, Right Angle (2.1x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
2.65 A |
50 W |
19 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A190-11E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug (2.1x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
2.65 A |
50 W |
19 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A240-11E03-Level-VI
Cincon |
6 |
- |
|
- |
Required |
- |
12 mm |
- |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug (2.1x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
2.1 A |
50 W |
24 VDC |
Universal |
Details |
TRH50A |
- |
10.582189 oz |
52 mm |
|
|
TRH50A480-01E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug, Right Angle (2.1x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
1.05 A |
50 W |
48 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH50A480-11E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
CE, cUL, EN60950-1, IEC60950-1, GS, UL60950-1 |
12 mm |
PSE |
Center Positive |
Barrel Connector |
Convection |
2.1 mm Barrel Plug (2.1x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
1.05 A |
50 W |
48 VDC |
Universal |
Details |
TRH50A |
PSE |
- |
52 mm |
|
|
TRH70A120-40E01-Level-VI
Cincon |
- |
- |
|
- |
Required |
- |
9.5 mm |
- |
Center Positive |
Barrel Connector |
Convection |
1.7 mm Barrel Plug, Right Angle (1.7x4) |
720 mm |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
5.8 A |
70 W |
12 VDC |
Universal |
Details |
TRH70A |
- |
- |
52 mm |
|
|
TRH70A120-48E01-Level-VI
Cincon |
- |
- |
|
- |
Required |
- |
9.5 mm |
- |
Center Positive |
Barrel Connector |
Convection |
1.5 mm Barrel Plug, Right Angle (1.5x5) |
720 mm |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
5.8 A |
70 W |
12 VDC |
Universal |
Details |
TRH70A |
- |
- |
52 mm |
|
|
TRH70A180-36E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
- |
9 mm |
- |
Center Positive |
Barrel Connector |
Convection |
1.35 mm Barrel Plug, Right Angle (1.35x3.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
3.9 A |
70 W |
18 VDC |
Universal |
Details |
TRH70A |
- |
- |
52 mm |
|
|
TRH70A180-40E03-Level-VI
Cincon |
- |
- |
|
- |
Required |
- |
9.5 mm |
- |
Center Positive |
Barrel Connector |
Convection |
1.7 mm Barrel Plug, Right Angle (1.7x4) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
3.9 A |
70 W |
18 VDC |
Universal |
Details |
TRH70A |
- |
- |
52 mm |
|
|
TRH70A360-02E02-Level-VI
Cincon |
- |
- |
|
- |
Required |
EN60950-1, IEC60950-1, UL60950-1 |
12 mm |
EN60950-1, IEC60950-1, UL60950-1 |
Center Positive |
Barrel Connector |
- |
2.5 mm Barrel Plug, Right Angle (2.5x5.5) |
1.2 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
- |
- |
- |
120 mm |
Regulated |
+ 70 C |
- |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
2 A |
70 W |
36 VDC |
Universal |
Details |
TRH70A |
- |
- |
52 mm |
|
|
TRH70A360-12E02-Level-VI
Cincon |
- |
- |
|
- |
Required |
EN60950-1, IEC60950-1, UL60950-1 |
12 mm |
EN60950-1, IEC60950-1, UL60950-1 |
Center Positive |
Barrel Connector |
- |
2.5 mm Barrel Plug (2.5x5.5) |
1.2 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
- |
- |
- |
120 mm |
Regulated |
+ 70 C |
- |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
2 A |
70 W |
36 VDC |
Universal |
Details |
TRH70A |
- |
- |
52 mm |
|
|
TRH70A480-12E03-Level-VI
Cincon |
8 |
- |
|
- |
Required |
- |
12 mm |
- |
Center Positive |
Barrel Connector |
Convection |
2.5 mm Barrel Plug (2.5x5.5) |
1.8 m |
Level VI |
1 |
31 mm |
Industrial |
90 VAC to 264 VAC |
264 VAC |
90 VAC |
4.24 kVDC |
120 mm |
Regulated |
+ 70 C |
External |
- 20 C |
Desktop |
1 Output |
- 20 C to + 70 C |
1.5 A |
70 W |
48 VDC |
Universal |
Details |
TRH70A |
- |
10.582189 oz |
52 mm |