-
ManufacturerHARTING (33)Molex (6)Phoenix Contact (67)TE Connectivity AMP Connectors (14)Weidmuller (1)
-
Additional FeatureUL 94V-0 (1)
-
Connector TypeInsert without Contacts (9)Insert (10)Insert with Integrated Frame (1)
-
Contact FinishSilver (11)
-
Contact Finish MatingNOT SPECIFIED (1)
-
Contact MaterialsCopper Alloy (9)Brass (2)COPPER ALLOY (2)
-
Contact PlatingSilver (9)
-
Contact TypeCK 2.5-ED (8)CK 1.6-ED, CK 2.5-ED (1)
-
Current Rating16A (11)55A (2)13A (1)
-
Current Rating (Amps)24A (2)19A (4)
-
Depth32mm (4)34.6mm (1)
-
DIN ConformanceNO (5)
-
ECCN CodeEAR99 (2)
-
Factory Lead Time7 Weeks (9)12 Weeks (10)4 Weeks (1)
-
Flammability RatingUL94 V-0 (14)
-
GenderMale (13)Female (7)
-
Housing MaterialPolycarbonate (PC) (12)Polyamide (PA), Nylon (5)Polycarbonate (PC), Glass Filled (3)
-
HTS Code8536.69.40.40 (1)8536.69.40.30 (1)
-
IEC ConformanceNO (5)
-
JESD-609 Codee4 (4)
-
Lead FreeLead Free (2)
-
Length84mm (4)75mm (1)64mm (1)
-
Material Flammability RatingUL94 V-0 (20)
-
Max Current Rating16A (5)63A (1)
-
MIL ConformanceNO (5)
-
Moisture Sensitivity Level (MSL)1 (Unlimited) (20)
-
MountPanel (1)
-
Number of Decks1 (1)
-
Number of Pins18 (2)32 (2)46 (1)10 (1)3 (1)4 (1)
-
Number of Positions18+Ground (2)32+Ground (2)46+Ground (1)10+Ground (3)16+Ground (4)3+Ground (2)4+Ground (1)6+Ground (1)8+24+Ground (1)10 (1)16 (2)
-
Number of Rows1 (2)
-
Number of Ways4 (1)
-
Operating Temperature-40u00b0C~125u00b0C (18)-40u00b0C~100u00b0C (2)
-
OptionGENERAL PURPOSE (5)
-
OrientationStraight (5)Right Angle (1)
-
PackagingBulk (20)
-
Part StatusActive (20)
-
Pbfree Codeyes (20)
-
Pitch10.16mm (1)
-
Published2015 (6)2011 (2)2016 (2)2017 (4)2012 (1)2009 (5)
-
RatingsIP66 (6)
-
Reach Compliance Codenot_compliant (6)unknown (1)
-
RoHS StatusRoHS Compliant (20)
-
Safety ApprovalUL (1)
-
SeriesHEAVYCONu00ae BB 18 (2)HEAVYCONu00ae BB 32 (2)HEAVYCONu00ae BB 46 (1)HEAVYCONu00ae BB10 (1)HEAVYCONu00ae B16 (4)HEAVYCONu00ae A3 (1)HEAVYCONu00ae A4 (1)HEAVYCONu00ae A10 (2)HEAVYCONu00ae A16 (2)Varioconu00ae TFS (1)Varioconu00ae AML (1)HEAVYCONu00ae K8/24 (1)HEAVYCONu00ae B10 (1)
-
SizeB10 (4)B16 (6)B24 (1)B6 (1)D7 (2)A10 (1)D15 (1)D25 (2)
-
Terminal and Terminal Block TypeBARRIER STRIP TERMINAL BLOCK (1)
-
Termination StyleCrimp (9)Screw (10)Solder (1)
-
Voltage - Rated500V (2)
-
Voltage Rated500V (5)600V (12)230V (1)
-
Wire Cross Section16 mm2 (1)
-
Wire Gauge6 AWG (1)
Attribute column
Categories
Heavy Duty Connectors Modules
Product |
Inventory |
Pricing(USD) |
Quantity |
Datasheet |
RoHS |
Additional Feature |
Connector Type |
Contact Finish |
Contact Finish Mating |
Contact Materials |
Contact Plating |
Contact Type |
Current Rating |
Current Rating (Amps) |
Depth |
DIN Conformance |
ECCN Code |
Factory Lead Time |
Flammability Rating |
Gender |
Housing Material |
HTS Code |
IEC Conformance |
JESD-609 Code |
Lead Free |
Length |
Material Flammability Rating |
Max Current Rating |
MIL Conformance |
Moisture Sensitivity Level (MSL) |
Mount |
Number of Decks |
Number of Pins |
Number of Positions |
Number of Rows |
Number of Ways |
Operating Temperature |
Option |
Orientation |
Packaging |
Part Status |
Pbfree Code |
Pitch |
Published |
Ratings |
Reach Compliance Code |
RoHS Status |
Safety Approval |
Series |
Size |
Terminal and Terminal Block Type |
Termination Style |
Voltage - Rated |
Voltage Rated |
Wire Cross Section |
Wire Gauge |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1584716
Phoenix Contact |
- |
- |
|
Datasheet |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
- |
- |
- |
7 Weeks |
UL94 V-0 |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
18 |
18+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2015 |
- |
- |
RoHS Compliant |
- |
HEAVYCONu00ae BB 18 |
B10 |
- |
Crimp |
- |
500V |
- |
- |
|
1584729
Phoenix Contact |
- |
- |
|
- |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
- |
- |
- |
12 Weeks |
UL94 V-0 |
Female |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
18 |
18+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2015 |
- |
- |
RoHS Compliant |
- |
HEAVYCONu00ae BB 18 |
B10 |
- |
Crimp |
- |
500V |
- |
- |
|
1584732
Phoenix Contact |
- |
- |
|
Datasheet |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
- |
- |
- |
12 Weeks |
UL94 V-0 |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
32 |
32+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2015 |
- |
- |
RoHS Compliant |
- |
HEAVYCONu00ae BB 32 |
B16 |
- |
Crimp |
- |
500V |
- |
- |
|
1584745
Phoenix Contact |
- |
- |
|
Datasheet |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
- |
- |
- |
7 Weeks |
UL94 V-0 |
Female |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
32 |
32+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2015 |
- |
- |
RoHS Compliant |
- |
HEAVYCONu00ae BB 32 |
B16 |
- |
Crimp |
500V |
- |
- |
- |
|
1584758
Phoenix Contact |
12 |
- |
|
- |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
- |
- |
- |
7 Weeks |
UL94 V-0 |
Female |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
46 |
46+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2015 |
- |
- |
RoHS Compliant |
- |
HEAVYCONu00ae BB 46 |
B24 |
- |
Crimp |
- |
500V |
- |
- |
|
1584774
Phoenix Contact |
- |
- |
|
Datasheet |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
- |
- |
- |
7 Weeks |
UL94 V-0 |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
10 |
10+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2015 |
- |
- |
RoHS Compliant |
- |
HEAVYCONu00ae BB10 |
B6 |
- |
Crimp |
500V |
- |
- |
- |
|
1584910
Phoenix Contact |
26 |
- |
|
- |
- |
Insert without Contacts |
- |
- |
- |
Silver |
CK 2.5-ED |
16A |
- |
32mm |
- |
- |
7 Weeks |
UL94 V-0 |
Male |
Polyamide (PA), Nylon |
- |
- |
- |
- |
84mm |
UL94 V-0 |
16A |
- |
1 (Unlimited) |
- |
- |
- |
16+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
Straight |
Bulk |
Active |
yes |
- |
2011 |
IP66 |
- |
RoHS Compliant |
- |
HEAVYCONu00ae B16 |
B16 |
- |
Crimp |
- |
500V |
- |
- |
|
1585210
Phoenix Contact |
- |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
- |
24A |
- |
- |
- |
12 Weeks |
- |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
3 |
3+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2016 |
- |
not_compliant |
RoHS Compliant |
- |
HEAVYCONu00ae A3 |
D7 |
- |
Screw |
- |
600V |
- |
- |
|
1585236
Phoenix Contact |
- |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
- |
24A |
- |
- |
- |
12 Weeks |
- |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
4 |
4+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2016 |
- |
not_compliant |
RoHS Compliant |
- |
HEAVYCONu00ae A4 |
D7 |
- |
Screw |
- |
600V |
- |
- |
|
1585294
Phoenix Contact |
49 |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
- |
19A |
- |
- |
- |
12 Weeks |
- |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
- |
10+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2017 |
- |
not_compliant |
RoHS Compliant |
- |
HEAVYCONu00ae A10 |
A10 |
- |
Screw |
- |
600V |
- |
- |
|
1585304
Phoenix Contact |
2 |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
- |
19A |
- |
- |
- |
7 Weeks |
- |
Female |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
- |
10+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2017 |
- |
not_compliant |
RoHS Compliant |
- |
HEAVYCONu00ae A10 |
D15 |
- |
Screw |
- |
600V |
- |
- |
|
1585317
Phoenix Contact |
- |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
- |
19A |
- |
- |
- |
12 Weeks |
- |
Male |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
- |
16+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2017 |
- |
not_compliant |
RoHS Compliant |
- |
HEAVYCONu00ae A16 |
D25 |
- |
Screw |
- |
600V |
- |
- |
|
1585320
Phoenix Contact |
39 |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
- |
19A |
- |
- |
- |
12 Weeks |
- |
Female |
Polycarbonate (PC) |
- |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
- |
- |
16+Ground |
- |
- |
-40u00b0C~125u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2017 |
- |
not_compliant |
RoHS Compliant |
- |
HEAVYCONu00ae A16 |
D25 |
- |
Screw |
- |
600V |
- |
- |
|
1607488
Phoenix Contact |
10 |
- |
|
- |
UL 94V-0 |
Insert with Integrated Frame |
Silver |
- |
Brass |
- |
- |
55A |
- |
- |
- |
EAR99 |
7 Weeks |
UL94 V-0 |
Female |
Polyamide (PA), Nylon |
8536.69.40.40 |
- |
- |
- |
- |
UL94 V-0 |
- |
- |
1 (Unlimited) |
- |
1 |
- |
3+Ground |
1 |
4 |
-40u00b0C~100u00b0C |
- |
- |
Bulk |
Active |
yes |
- |
2011 |
- |
- |
RoHS Compliant |
UL |
Varioconu00ae TFS |
- |
BARRIER STRIP TERMINAL BLOCK |
Screw |
- |
600V |
16 mm2 |
6 AWG |
|
1607537
Phoenix Contact |
48 |
- |
|
- |
- |
Insert |
Silver |
- |
Brass |
- |
- |
55A |
- |
- |
- |
- |
7 Weeks |
UL94 V-0 |
Male |
Polyamide (PA), Nylon |
- |
- |
- |
- |
75mm |
UL94 V-0 |
63A |
- |
1 (Unlimited) |
- |
- |
- |
6+Ground |
1 |
- |
-40u00b0C~100u00b0C |
- |
Right Angle |
Bulk |
Active |
yes |
10.16mm |
2012 |
- |
- |
RoHS Compliant |
- |
Varioconu00ae AML |
- |
- |
Solder |
- |
600V |
- |
- |
|
1636318
Phoenix Contact |
40 |
- |
|
- |
- |
Insert without Contacts |
- |
NOT SPECIFIED |
COPPER ALLOY |
Silver |
CK 1.6-ED, CK 2.5-ED |
16A |
- |
- |
NO |
- |
4 Weeks |
UL94 V-0 |
Male |
Polyamide (PA), Nylon |
- |
NO |
- |
- |
- |
UL94 V-0 |
- |
NO |
1 (Unlimited) |
- |
- |
- |
8+24+Ground |
- |
- |
-40u00b0C~125u00b0C |
GENERAL PURPOSE |
- |
Bulk |
Active |
yes |
- |
2009 |
IP66 |
- |
RoHS Compliant |
- |
HEAVYCONu00ae K8/24 |
B10 |
- |
Crimp |
- |
230V |
- |
- |
|
1648173
Phoenix Contact |
- |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
16A |
- |
32mm |
NO |
EAR99 |
12 Weeks |
UL94 V-0 |
Male |
Polycarbonate (PC), Glass Filled |
8536.69.40.30 |
NO |
e4 |
- |
64mm |
UL94 V-0 |
16A |
NO |
1 (Unlimited) |
Panel |
- |
- |
10 |
- |
- |
-40u00b0C~125u00b0C |
GENERAL PURPOSE |
Straight |
Bulk |
Active |
yes |
- |
2009 |
IP66 |
unknown |
RoHS Compliant |
- |
HEAVYCONu00ae B10 |
B10 |
- |
Screw |
- |
600V |
- |
- |
|
1648238
Phoenix Contact |
- |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
16A |
- |
32mm |
NO |
- |
12 Weeks |
UL94 V-0 |
Male |
Polycarbonate (PC), Glass Filled |
- |
NO |
e4 |
Lead Free |
84mm |
UL94 V-0 |
16A |
NO |
1 (Unlimited) |
- |
- |
- |
16 |
- |
- |
-40u00b0C~125u00b0C |
GENERAL PURPOSE |
Straight |
Bulk |
Active |
yes |
- |
2009 |
IP66 |
- |
RoHS Compliant |
- |
HEAVYCONu00ae B16 |
B16 |
- |
Screw |
- |
600V |
- |
- |
|
1648241
Phoenix Contact |
- |
- |
|
- |
- |
Insert |
Silver |
- |
Copper Alloy |
- |
- |
16A |
- |
34.6mm |
NO |
- |
12 Weeks |
UL94 V-0 |
Female |
Polycarbonate (PC), Glass Filled |
- |
NO |
e4 |
Lead Free |
84mm |
UL94 V-0 |
16A |
NO |
1 (Unlimited) |
- |
- |
- |
16 |
- |
- |
-40u00b0C~125u00b0C |
GENERAL PURPOSE |
Straight |
Bulk |
Active |
yes |
- |
2009 |
IP66 |
- |
RoHS Compliant |
- |
HEAVYCONu00ae B16 |
B16 |
- |
Screw |
- |
600V |
- |
- |
|
1648270
Phoenix Contact |
20 |
- |
|
- |
- |
Insert without Contacts |
- |
- |
COPPER ALLOY |
Silver |
CK 2.5-ED |
13A |
- |
32mm |
NO |
- |
7 Weeks |
UL94 V-0 |
Male |
Polyamide (PA), Nylon |
- |
NO |
e4 |
- |
84mm |
UL94 V-0 |
16A |
NO |
1 (Unlimited) |
- |
- |
- |
16+Ground |
- |
- |
-40u00b0C~125u00b0C |
GENERAL PURPOSE |
Straight |
Bulk |
Active |
yes |
- |
2009 |
IP66 |
- |
RoHS Compliant |
- |
HEAVYCONu00ae B16 |
B16 |
- |
Crimp |
- |
600V |
- |
- |
